RADICAL PASSIVEHAUS BUNGALOW

New build

Radical Passivhaus bungalow

Radical Passivhaus bungalow

Custom New-build

The objective of this project was to replace the original 1960’s bungalow in Chester with a modern, extended & certified Passivhaus home with dramatically reduced energy use. At the same time, the client wanted to maximise the amount of Solar PV on the roof not only to power the house but to sell it back to the grid in the summer to offset bills in the winter. The client also wanted an off-site build approach to minimise the construction time.

Getting the project started was complicated by having to archaeologists present while the excavations were underway. Rainwater harvesting was added during the project, making 10,000 litres of stored rainwater available for flushing toilets, washing & for use in the garden. This proved to be foresightful given the drought that occurred in the summer of 2026.

Architects:

Raise Architects

Passivehaus Design:

EcoVert Solution

BUILDING MATERIALS:
Passive slab foundation – Isoquick
Walls and roof –  offsite built, consisting of Kingspan SIPS panel construction from Point 1
Additional external wall insulation & roof insulation added on site was 50mm Kingspan
External & internal membranes & tapes from Partel achieving airtightness of 0.35ach @ 50pa
Internorm Passivhaus windows and doors incorporating in-built electric blinds
Metal roof and Krop gutters from Pagurek
BUILDING SERVICES:
MVHR – Zehnder Comfoair
UFH – Ambiente
Waste Water Heat Recovery System –
Rainwater harvesting – 10,000 litre tank & system from Rain Director
14.4kWp roof integrated & flat roof Solar PV panels
SolarEdge hybrid inverterswith 2 x 10kWh Battery Storage, solar immersion switch, home director,  car charger
Samsung gen 7 R290 ASHP with Samsung Joule water storage
BUILDING CONTROL:
Stroma